logo
products
PRODUCTS DETAILS
Home > Products >
R134A & R1234YF Dual Stem Flushing & Recovery AC Service Station

R134A & R1234YF Dual Stem Flushing & Recovery AC Service Station

MOQ: 5
Price: USD
Standard Packaging: cartons
Delivery Period: 10-15 days
Payment Method: L/C, D/A, D/P, T/T
Supply Capacity: 100pcs/Month
Detail Information
Place of Origin
China
Brand Name
CAROZZA
Certification
CE
Model Number
SAC-1000N
Current:
8/12A
Compressor:
12.12cc
Vacuum Pump:
4.5CFM,3Pa
New Oil Bottle:
300ml,2PCS(PAG,POE)
Used Oi Bottle:
500ml
Tank Capacity:
12L,2PCS(R134a,R1234yf)
Work Max.pressure:
20bar
Minimum Order Quantity:
5
Price:
USD
Packaging Details:
cartons
Delivery Time:
10-15 days
Payment Terms:
L/C, D/A, D/P, T/T
Supply Ability:
100pcs/Month
Highlight:

Flushing & Recovery AC Service Station

,

Dual Stem AC Service Station

,

R134A AC Service Station

Product Description

R134a& R1234yf Dual stem Flushing & Recovery A/C Machine

 

The characteristc of  A/C service station : (Reliable,Stable, Durable)

 

*Dual system forR1234a&R1234yf.
*Controlled entirely by solenoid valves.
*Integrated,modular design,easy to maintain.
*Self diagnosis and protection technology,stable operation.
*Easy to operation and suitable for everybody.

 

 

The functions : (Flush,Recovery,Vacuum,Recharge)

 

*Pulse fushing to exchange refrigerant oil
*Automatic recovering/recycling(R134a,R1234yf).
*Automatic/manual used oil drain
*Timing vacuum
*Automatic/Manual new oilinjection(PAG,POE).
*Quantitative recharging(R134a,R1234yf).
*Fully automatic mode.
*Database forrefrigerant & oil
*Print(service time,materials,etc.).
*Refrigerant transfer(supply).
*Equipment self-diagnosis and self-protection.
*Maintenance procedures(cleaning,empty,etc.)

 

 

 

The parameter :(voltage,Pressure,Accyracy)

 

VoItage:□ AC220V/50Hz~60Hz□AC110V~60Hz
Current:8/12A
Compressor:12.12cc
Vacuumpump:4.5CFM,3Pa
Newoilbottle:300ml,2PCS(PAG,POE)
Used oil bottle:500ml
Tankcapacity:12L,2PCS(R134a,R1234yf)
Load cellprecision:30kg±10g,2PCS(R134a,R1234yf)
Load cell precision(oilbotle):6kg±5g
LCD:240*128
Work max.pressure:20bar
Size(LxWxH):670x730x1445mm
Gross weight:128kg

 


The Maintenance of A/C service station :


1.Avoid sunshine,rain,impact,dumping
2.Used underventilated conditions
3.Regular maintenance.
4.Empty old bottle in time
5.Dont tilt upside down

 

 

MODELS SAC-1000D
VOLTAGE  
FUNCTION Recovery/Recycle
Recharging
Vacuum
Refill new oil- Manual/Automatic
Uesd oil seperation & drain
Flushing
Port for can refrigerant
LCD
Printer
Database
R134a or R1235yf
Full-automatic

 

 

 

 

 

 

products
PRODUCTS DETAILS
R134A & R1234YF Dual Stem Flushing & Recovery AC Service Station
MOQ: 5
Price: USD
Standard Packaging: cartons
Delivery Period: 10-15 days
Payment Method: L/C, D/A, D/P, T/T
Supply Capacity: 100pcs/Month
Detail Information
Place of Origin
China
Brand Name
CAROZZA
Certification
CE
Model Number
SAC-1000N
Current:
8/12A
Compressor:
12.12cc
Vacuum Pump:
4.5CFM,3Pa
New Oil Bottle:
300ml,2PCS(PAG,POE)
Used Oi Bottle:
500ml
Tank Capacity:
12L,2PCS(R134a,R1234yf)
Work Max.pressure:
20bar
Minimum Order Quantity:
5
Price:
USD
Packaging Details:
cartons
Delivery Time:
10-15 days
Payment Terms:
L/C, D/A, D/P, T/T
Supply Ability:
100pcs/Month
Highlight

Flushing & Recovery AC Service Station

,

Dual Stem AC Service Station

,

R134A AC Service Station

Product Description

R134a& R1234yf Dual stem Flushing & Recovery A/C Machine

 

The characteristc of  A/C service station : (Reliable,Stable, Durable)

 

*Dual system forR1234a&R1234yf.
*Controlled entirely by solenoid valves.
*Integrated,modular design,easy to maintain.
*Self diagnosis and protection technology,stable operation.
*Easy to operation and suitable for everybody.

 

 

The functions : (Flush,Recovery,Vacuum,Recharge)

 

*Pulse fushing to exchange refrigerant oil
*Automatic recovering/recycling(R134a,R1234yf).
*Automatic/manual used oil drain
*Timing vacuum
*Automatic/Manual new oilinjection(PAG,POE).
*Quantitative recharging(R134a,R1234yf).
*Fully automatic mode.
*Database forrefrigerant & oil
*Print(service time,materials,etc.).
*Refrigerant transfer(supply).
*Equipment self-diagnosis and self-protection.
*Maintenance procedures(cleaning,empty,etc.)

 

 

 

The parameter :(voltage,Pressure,Accyracy)

 

VoItage:□ AC220V/50Hz~60Hz□AC110V~60Hz
Current:8/12A
Compressor:12.12cc
Vacuumpump:4.5CFM,3Pa
Newoilbottle:300ml,2PCS(PAG,POE)
Used oil bottle:500ml
Tankcapacity:12L,2PCS(R134a,R1234yf)
Load cellprecision:30kg±10g,2PCS(R134a,R1234yf)
Load cell precision(oilbotle):6kg±5g
LCD:240*128
Work max.pressure:20bar
Size(LxWxH):670x730x1445mm
Gross weight:128kg

 


The Maintenance of A/C service station :


1.Avoid sunshine,rain,impact,dumping
2.Used underventilated conditions
3.Regular maintenance.
4.Empty old bottle in time
5.Dont tilt upside down

 

 

MODELS SAC-1000D
VOLTAGE  
FUNCTION Recovery/Recycle
Recharging
Vacuum
Refill new oil- Manual/Automatic
Uesd oil seperation & drain
Flushing
Port for can refrigerant
LCD
Printer
Database
R134a or R1235yf
Full-automatic